TRS100 opens a new chapter in quantitative drug analysis using the power of the transmission Raman technology

Quantitative Analysis of Tablets, Capsules and Powders

Streamlined Quality Control Testing

  • Assay hundreds of tablets or capsules in minutes
  • Works with intact capsules, coated tablets and 10mm thickness
  • No sample preparation, wet chemistry or skilled resource
  • Quantify APIs and excipients in a single measurement
  • LOQ as low as 0.1% w/w - Even for polymorphs in intact tablets
  • Lean calibration models - Easy to build and maintain
  • Methods approved by regulators

 

 

Transmission Raman for Quality Control

The TRS100 enables high-throughput, non-destructive, non-invasive bulk assay of all common dosage forms without sample preparation. Easier to implement than other spectroscopic methods, Cobalt’s transmission Raman (TRS™) technology allows simple method-development and deployment in QC applications.

 

Replacing HPLC

Using a single TRS100 an operator can replace 8-10 HPLC units and their operators. The TRS100 has a flexible sample tray system that can work with coated tablets, intact capsules, glass vials and powders to measure hundreds of samples per hour. Sample preparation and consumable items are not required. CU testing methods using Transmission Raman are approved by regulators. Switching to TRS from HPLC allows significant cost savings per batch and streamlined method development.

 

Other Applications

The TRS100 can be used for other applications, including quantitative measurement of polymorphic content in intact tablets <1% w/w – significantly better than XRPD. For formulation development work, the ease and flexibility of model building makes TRS a practical alternative to wet methods.

 

Content Uniformity Testing

Replacing HPLC Methods – Reducing Resource​

  • Whole tablet/capsule analysis – no sub-sampling
  • Works with intact samples up to 10mm thick
  • No sample preparation, wet chemistry or skilled testing resource
  • LOQ 0.1-1% w/w
  • Methods approved by regulators

 

Transmission Raman Spectroscopy

Transmission Raman spectroscopy (TRS) is ideal for high throughput content uniformity analysis. A TRS measurement takes only a few seconds per sample with good accuracy, precision and linearity of response. TRS technology is specific and sensitive for nearly all APIs, excipients and lubricants but is largely insensitive to interference from water/moisture, particle density or surface coatings.

 

CU Testing

The TRS100 needs no consumables or solvents and no preparatory chemical skills. A single TRS100 CU batch report can be completed in <30 minutes from start to finish, which allows a high throughput for the QC function and low resource usage compared to traditional HPLC methods.

Compared with NIR, transmission Raman methods are easier to develop as scattering effects, such as those due to differences in tablet compaction, have a much smaller impact on the prediction result. TRS is quicker, has a higher sensitivity (lower % LOD/LOQ), can penetrate through thick samples and has easy-to-understand distinct spectral features from each formulation component.

 

Regulatory Compliance

TRS100 methods are compatible with regulatory requirements as an alternative to HPLC for content uniformity testing – see this webinar. The instrument and software are designed to meet relevant USP, EP and 21 CFR part 11 requirements.

 

Polymorph Quantification

Measuring Polymorph Concentration in Dosage Forms

 

Detecting Low Concentrations Easily

Most active pharmaceutical ingredients (APIs) are crystalline materials with a well-defined polymorphic form. Manufacturing or processing can change that form, and, increasingly, amorphous APIs are used by formulators to increase bioavailability. The TRS100 can directly measure low-energy crystalline vibrational modes (the phonon mode region) to quantify polymorph content in seconds and to a high precision in intact, formulated samples.

The most common technique for quantitative polymorph analysis is XRPD, which has a sensitivity limit of around 5% w/w and requires tablets to be crushed and sampled. The TRS100 can detect residual polymorphs in a fully formulated amorphous API tablet with a limit of detection (LOD) of 0.1-1% w/w. The LOD is comparable with ssNMR but requires no sample preparation, is much quicker and requires less resource.

Dimensions: 1124 mm wide / 521 mm high / 575 mm deep

 

Regulatory

21 CFR Part 11 compliant
Meets relevant USP and EP guidance

LaserClass 1 laser
830nm
Power

90-264VAC 50-60Hz

SoftwareRequires minimum of Windows 7 Pro OS
Supplied with Cobalt's ContentQC™ analysis and management software
Integrated Eigenvector Solo chemometrics engine
Sample Trays

Standard trays for common capsule and tablet sizes
Customisable tray designs accommodate any sample 
Optional Beam Enhancer™ technology available for increased speed and sensitivity